The company has obtained the Certificate of compliance of System of a quality management (ISO 9001:2000)
Early stopping of water treatment plant (WTP) and switching-off of system of greasing at metal temperature of high-pressure cylinder and intermediate-pressure cylinder in a zone of the distribution of steam 250-270˚С.
Rising temperatures, which allowed WTP shutdown of pumps and lubrication systems at 80-100 C, reduces the time the withdrawal of repairs to two - two and a half days instead of five. Joint application of technology early stopped WTP and cooling technology reduces the time to repair the turbine output to one and a half - one day. In the case of forced cooling air to the installation of ejector cylinders being cooled to a temperature of 250-270 C would be 24 hours.
The complex includes:
- Implementation of the calculations and the development of project documentation
- Issuance of technical documentation for the installation of resistance thermometers.
- A collaboration with the customer test program.
- Technical management introduction development.
- Holding up works.
- Permission to stop and disable the WTP pump lubrication system at a temperature of 250-270 C. The metal (based on the results of tests conducted).
Oil repellence coating prevents the spreading of oil, there is contraction of oil film, resulting in oil on the surface of the shaft going into individual drops. Under the influence of centrifugal forces tearing occurs oil droplets from the shaft, which allows practically to stop the oil leak through the seal.
The program of work includes:
- Development of documentation, including application of technology oil repellence cover.
- Delivery of the required number of reagent.
- Technical guidance on applying oil repellence cover.
A detailed techno-commercial offer, you can receive, by sending an e-mail mail@lenturbo.ru or fax (812) 531-20-20